 DTAM65 Series
65 Watt Single Output AC/DC Medical Desktop Adapter FEATURES
LED Option High Reliability Universal Input 100% Hi-Pot Tested AC Inlet: IEC 320-C14 100% BURN-IN Tested Safety Approvals, EMC Compliance
SPECIFICATIONS: DTAM65 Series
All specifications are based on 25oC, Nominal Input Voltage, and Maximum Output Current unless otherwise noted. We reserve the right to change specifications based on technological advances. INPUT SPECIFICATIONS Input Voltage Range Rated Input Voltage Range Input Frequency Input Current Inrush Current OUTPUT SPECIFICATIONS Output Current Output Voltage Line Regulation Ripple & Noise (20MHz BW) Hold Up Time PROTECTION Short Circuit Protection Over Voltage Protection Over Power Protection GENERAL SPECIFICATIONS Efficiency No Load Power Consumption ENVIRONMENTAL SPECIFICATIONS Operating Temperature Storage Temperature MTBF PHYSICAL SPECIFICATIONS Weight Dimensions AC Input Warranty SAFETY & EMI Safety Standards EMC Standards 90 - 264VAC (Full Range) 100 - 240VAC 47 - 63Hz 2A max. 30A at maximum at 115VAC,
60A at maximum at 230VAC
See Table See Table < 1% See Table >16.6ms typical at full load and 115VAC Auto recover Auto recover Auto recover 5V, 12V > 75% Avg. 115 or 230VAC 15V ~ 48V > 85% Avg. 115 or 230VAC (Meet CEC 2008) < 0.5W at 230VAC 0C to +70C ambient (derating at 2.5%/C from 50C to 70C) -10C to +85C >100,000 hours at full load and 25C ambient temperature Approximately 12oz. 132.0(L) x 69.00(W) x 40.00(H) mm IEC 320-C14 Inlet 2 years UL/c-UL UL60601-1, TUV EN60601-1, CB IEC60601-1 EN60601-1-2, FCC Part 18 Class B, EN55011 Class B, CE
Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833 603-778-2300 www.wallindustries.com Fax 603-778-9797
DTAM65 Series
65 Watt Single Output AC/DC Medical Desktop Adapter OUTPUT VOLTAGE / CURRENT RATING CHART
Model DTAM040A1Y05X DTAM060A1Y12X DTAM060A1Y15X DTAM065A1Y18X DTAM065A1Y24X DTAM065A1Y36X DTAM065A1Y48X Output Voltage 5 VDC 12 VDC 15 VDC 18 VDC 24 VDC 36 VDC 48 VDC Output Current 8A 5A 4A 3.6A 2.7A 1.8A 1.35A Output Power 40W 60W 60W 64.8W 64.8W 64.8W 64.8W Output Regulation 5% 5% 5% 3% 3% 3% 3% Ripple & Noise 100mVp-p 120mVp-p 150mVp-p 180mVp-p 240mVp-p 360mVp-p 480mVp-p
NOTES
1. The suffix X can be blank for no LED or L for a green LED. Contact factory for ordering details. 2. Ripple & Noise is measured at 20MHz bandwidth with a tantalum 10uF in parallel with a 0.1uF ceramic capacitor.
MECHANICAL DRAWING
STANDARD OUTPUT CABLE 1. AWM 1185#18AWG 1C+SHIELDING, UL 80C 300V VW-1, 1800mm. 2. AWM 1571#14~16AWG 1C+SHIELDING, UL 80C 30V VW-1, 1800mm. 3. Depends on customer's requirements. Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833 603-778-2300 www.wallindustries.com Fax 603-778-9797


▲Up To Search▲   

 
Price & Availability of DTAM060A1Y15X

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X